6
  • petrol

    Fuel

  • manual

    Transmission

DESCRIPTION

Miami, Florida, United States
HeatWave SuperQuiet® is the TOP selling and most sought after heat pump on the market. With a pure Titanium ThermoLink® Heat Exchanger at its core – the HeatWave SuperQuiet® Series offers you optimum return on your investment.

Making the right choice just got a whole lot easier. All of our HeatWave SuperQuiet® Heat Pumps are fully tested and certified by AHRI. Some of the HeatWave SuperQuiet® models are also ICEBREAKERS®, which heat and cool the pool. The ICEBREAKER® units extend the swimming season longer than any other heat pump by continuing to operate in low temperatures.

Rated in accordance with AHRI standard 1160. PoolSync Ready Now you can control your heat pump right through your smartphone. Change the mode to heat, cool or autotemp (when applicable), and set your temperature through the PoolSync app. *Additional purchase of PoolSync WiFi Controller required

- 50 Hz SQ225 SQ166R
Efficiency
KW Output 35.2 31.7
BTU Output 120,000 108,000
Coefficient of Performance (C.O.P) 6.5 5.6
KW Input 5.4 5.7
Electrical
Heat or Heat & Cool H H & C
Voltage/Hz/Phase
H – 200-240/50/1
D – 380-420/50/3 D D
Maximum Fuse Size D – 25 D – 25
Minimum Circuit Ampacity D – 16.2 D – 16.2
Refrigerant R410A R410A
Water Flow
A Heater Bypass Kit is required when flow rates exceed the maximum
Minimum/Maximum (m3/h) 6.8/15.9 6.8/15.9
Minimum/Maximum (gpm) 30/70 30/70
Physical
Weight (kg) 143 141
Weight (lb) 315 310
Length x Width x Height (cm) 87 x 87 x 112 87 x 87 x 112
Length x Width x Height (in) 34″ x 34″ x 44″ 34″ x 34″ x 44″
Shipping
Weight (kg) 162 159
Weight (lb) 355 350
Length x Width x Height (cm) 94 x 92 x 130 94 x 92 x 130
Length x Width x Height (in) 37″ x 36″ x 51″ 37″ x 36″ x 51″
-- -- 60 Hz SQ125 SQ145 SQ225 SQ120R SQ166R
BTUs (water temp/ambient air/relative humidity)
80/80/80 101,000 121,000 143,000 110,000 126,000
80/80/63 95,000 115,000 134,000 103,000 120,000
80/50/63 62,000 75,000 90,000 72,000 82,000
Coefficient of Performance
(water temp/ambient air/relative humidity)
80/80/80 6.5 7.1 6.5 5.5 5.6
80/80/63 6.1 6.8 6.1 5.3 5.3
80/50/63 4.0 4.2 4.0 4.0 4.0
Refrigerant R410A R410A R410A R410A R410A
Electrical
Heat or Heat & Cool H H H H & C H & C
kW Input 4.6 5.1 6.4 5.9 6.6
Voltage/Hz/Phase
A – 208-230/60/1
B – 200-230/60/3
E – 380-415/60/3
G – 460/60/3
A A, B & G A, B, E & G A & B A, B, E & G
Maximum Fuse Size A – 60 A – 60
B – 50
G – 20 A – 60
B – 50
E – 30
G – 25 A – 60
B – 50 A – 60
B – 50
E – 30
G – 25
Minimum Circuit Ampacity
Over Temperature Alarm Kit available: part number STK0221 for single phase, STK0222 for three phases. Strongly recommended for all spa applications. A – 40.5 A – 42.1
B – 31.0
G – 14.2 A – 42.1
B – 33.3
E – 18.4
G – 16.2 A – 38.5
B – 31.0 A – 42.1
B – 33.3
E – 18.4
G – 16.2
Water Flow
*A Heater Bypass Kit is required when flow rates exceed the maximum
Minimum/Maximum (gpm) 30/70 30/70 30/70 30/70 30/70
Physical
Weight (lbs) 258 305 315 273 310
Length x Width x Height (in)
34″ x 34″ x 44″ 34″ x 34″ x 44″ 34″ x 34″ x 44″ 34″ x 34″ x 44″ 34″ x 34″ x 44″
Shipping
Weight (lbs) 298 345 355 313 350
Length x Width x Height (in) 37″ x 36″ x 51″ 37″ x 36″ x 51″ 37″ x 36″ x 51″ 37″ x 36″ x 51″ 37″ x 36″ x 51″
Rated in accordance with AHRI standard 1160 water temp/ambient air/relative humidity

Features